Notes (*)   Irradiations were performed in November '98, with the 24 GeV/c CERN/PS proton beam. The cumulated fluence is 3 1014 cm-2.
(**) Irradiations were performed in April '99, with the 24 GeV/c CERN/PS proton beam. The cumulated fluence is 3 1014 cm-2.
(***) Irradiations were performed in July '99, with the 24 GeV/c CERN/PS proton beam. The cumulated fluence is 3 1014 cm-2.
(****) Irradiations were performed in November '99, with the 24 GeV/c CERN/PS proton beam. The cumulated fluence is 3 1014 cm-2.
The detectors were under 100 volts bias and were irradiated at -9 oC in a dry N2 atmosphere. All these irradiations have been performed by the University of Sheffield group and thanks, in particular, to C.M. Buttar, I. Dawson, C. Grigson, R.S. Harper.....


Performances of Hamamatsu (Ham.) and Micron (Mic.) ATLAS wedge detectors before and after irradiation (*)
Reverse current vs bias
Non irr. Ham. 98
Non irr. Ham. W12-37055 family
Non irr. Ham. SXX-37160 family (thin detectors)
Non irr. Mic. 98
Irradiated Ham. (*)
Irradiated Mic. 98  (*)
Irradiated Ham.  SXX-37160 (**)
Backplane capacitance vs bias
Non irr. Mic.
Non irradiated Ham. 300 and 250 micron thick.
Irradiated (*) Micron : 1732-2-1, 1732-2-2 1733-2-1
Irradiated  (*): STX41618-11, STX41618-12.
Interstrip capacitance
Non irr. Ham. W12

Non irr. Mic. 1733-2-2
Irr. Ham. STX41618-12, short strips  (*)
Irr. Ham. STX41618-12, long strips  (*)
Irr. Mic. 1732-2-1, short strip  (*)
Irr. Mic. 1732-2-2, short strip  (*)
Irr. Mic. 1732-2-2 long strip  (*)
Noise vs bias for irradiated detectors
Micron (*) 1732-2-1
Micron (*) 1733-2-1
Micron (*) 1732-2-2
Hamamatsu (*)   STX41618-11
Hamamatsu (**) SXX -37160 family (thin detectors)

Strip integrity Irradiated (*) MICRON 1732-1-1, 1732-2-2, 1733-2-1
Irradiated (*) Hamamatsu STX41618-12

Back  

HOME