! BANKname BANKtype !Comments
!
TABLE FRRH ! Forward Response Radial Hit
! (temporary bank)
! ATTributes:
! -----------
!COL ATT-name FMT Min Max !Comments
!
1 CELLNUM I 0 863 ! Cell Number
2 EDEP F ! Energy deposited (GeV)
3 DRIFT F ! Drift distance (10 micron)
4 RADIUS F -1.0 +1.0 ! Hit 'radius'= (R-Rmin)/(Rmax-Rmin)
! pos.(neg.) for 1.(2.) wire on readoutc
5 HITTYP I ! Type of hit (track,noise)
6 DRFSGN I 0 1 ! Drift sign (1=+, 0=-)
7 TRKHIS I 0 256 ! tracking history word
!
! RELations:
! ----------
!COL REL.bank TYPE INT.bank !Comments
! (COL)
8 STR DMT1 ! track no. in STR bank