! BANKname BANKtype !Comments ! TABLE FRRH ! Forward Response Radial Hit ! (temporary bank) ! ATTributes: ! ----------- !COL ATT-name FMT Min Max !Comments ! 1 CELLNUM I 0 863 ! Cell Number 2 EDEP F ! Energy deposited (GeV) 3 DRIFT F ! Drift distance (10 micron) 4 RADIUS F -1.0 +1.0 ! Hit 'radius'= (R-Rmin)/(Rmax-Rmin) ! pos.(neg.) for 1.(2.) wire on readoutc 5 HITTYP I ! Type of hit (track,noise) 6 DRFSGN I 0 1 ! Drift sign (1=+, 0=-) 7 TRKHIS I 0 256 ! tracking history word ! ! RELations: ! ---------- !COL REL.bank TYPE INT.bank !Comments ! (COL) 8 STR DMT1 ! track no. in STR bank END TABLE