! BANKname BANKtype ! Comments
!
TABLE F0R8 ! Forward Radial Chamber
! overal calibration constants
!
! ATTributes:
! -----------
!COL ATT-name FMT Min Max ! Comments
!
1 T0 F -INF +INF ! time offset (1/50 FADC clock)
2 DelD F -INF +INF ! aver. time difference of
! wire ends
3 DelT F 0. +INF ! propagation time on sense wire
! (1/50 FADC clock)
4 Vdrift F 0. +INF ! drift velocity (cm/(1/50 FADC-clock)
5 D0 F -INF +INF ! )
6 D1 F -INF +INF ! )
7 D2 F -INF +INF ! ) const. for close_wire_correction
8 C0 F 0. +INF ! )
9 C1 F 0. +INF ! )
10 DR F 0. +INF ! radius at which radial elctric field
! around sense wire passes over
! to constant field
11 Aloren F -PI +PI ! Lorentz angle at nominal field
12 Xi F -INF +INF ! Magnitude of chg div. distortion
13 Kappa F -INF +INF ! T and P correction to gas gain
!
END TABLE