The proposal is available as ( PS file of 46K ), which should be used to produce a printed copy or can be read in text format.
The first study was for an 8-fold detector with 50 micron pitch. It was not realistic since it assumed an infinite z acceptance. Nonetheless, the report is useful for defining the quantities used to evaluate the performance and for several informative plots.
The second study assumed the detector was 80cm long in z, with eight sensors of 10cm. The third study summarised the first two, and considered twelve other possible designs for Layer00.
One is for an 8-fold detector with 50 micron pitch and 8 sensors of 10cm each in z. This would require two readout chips per sensor giving a total of 128. The problem with this design is seen in the occupancy studies where 38% of tracks deposit their charge over 4 or more strips.
A second design is for a 12-fold detector with 75 micron pitch and 10 sensors in z (6 of 8cm and 4 or 6.5cm). Two 6.5cm long would be daisychained and readout together. This would require one readout chip per sensor giving a total of 96 readout chips. This design also makes optimum use of 4 inch silicon wafers from which three 8cm sensors and two 6.5cm sensors could be cut.
At the moment, we are working on a 14- or 16-fold design with 50 micron pitch and one readout chip per sensor. ...Watch this space for breaking news...
We are investigating the capacitance of the kapton cables using two methods and comparing the results. The first uses the program MAXWELL and gives results which indicate a capacitance of 45 pF per metre (with a substrate permitivity of 4.3, strip pitch of .1 mm, strip width of .025 mm, substrate thickness of .1mm and metal thickness of .005mm). Further studies show the effect of varying the thickness and the permitivity, as well as the result of stacking.
GianLuigi has looked at the increase in voltage which would be necessary to fully deplete p-in-n detectors as they become progressively more damaged due to radiation.
He assumes a radiation dose of 1MRad per year equivalent to 2.10^13 Neutrons per cm squared. He takes the CV parameterisation as found in the ATLAS TDR. The detector is assumed to run at -10C. Any favourable annealing effects are ignored, while reverse annealing was calculated assuming that the detector was allowed to heat to 20C for one week at the end of each year for maintenance purposes.
The figure shows the predicted evolution of the Voltage for 300 micron thick detectors. Time, in hours, is on the horizontal axis; voltages are on the vertical axis. After 3 years of operation it would be necessary to run the detectors at 150 volts.