| Sheet: | 189 | sheet 189 - 192 top left
| |||||||||
| Perform | Num | Num | Num | Average | Software | Num | |||||
| Pitch Adaptor: | Status:    | Action:          | Comment: | Measurements: | Analysis | Shorts | Breaks | ?Breaks | Capacitance | Status | Bad Lifts |
| PA-189-R1 | r-114 | Capacitance | 41.512 mm (28 microns) | Capacitance | Analyse | 0 | 0 | 0 | 0.45 | PASS | 0 |
| PA-189-R2 | r-122 | Capacitance | 41.521mm 28um pads | Capacitance | Analyse | 0 | 0 | 0 | 0.45 | PASS | 0 |
| PA-189-R3 | r-113 | Capacitance | 41.512mm | Capacitance | Analyse | 0 | 0 | 0 | 0.44 | PASS | 0 |
| PA-189-R4 | FAIL | Visual | Failed by CERN | ||||||||
| PA-189-P1 | p-114 | Capacitance | 41.535mm | Capacitance | Analyse | 0 | 0 | 0 | 0.51 | PASS | 0 |
| PA-189-P2 | p-126 | Capacitance | 41.530mm | Capacitance | Analyse | 0 | 0 | 0 | 0.5 | PASS | 0 |
| PA-189-P3 | p-126 | Capacitance | 41.530mm 28um pads | Capacitance | Analyse | 0 | 0 | 0 | 0.5 | PASS | 0 |
| PA-189-P4 | p-120 | Capacitance | 41.527mm | Capacitance | Analyse | 0 | 0 | 0 | 0.49 | PASS | 0 |