"Time & Date" "Vacuum (mbar)" "Cap (fF)" "T (avg module)" "T (centre cool)" "T (bottom cool)" "T (centre)" "T (top)" "T input" "T output" "T feedback" "CO2 Pressure" "CO2 Flow" "Current 1" "Current 2" "HV1" "HV2 " "Leakage HV1" "Leakage HV2" "Comment" "19/8/2006" "#VALUE!" 10:28:00 AM 1.20E-004 -2 22 22 22 22 22 25 25 25 9 0 0 0 0 0 0 0 "CV plots say ~-30V for r and phi" 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 -50 -50 -30 -0.08 10:50:00 AM 1.00E-004 -40 -10 -14 -6 -13 -5 -28 -23 22 13 16 3.88 3.73 -50 -50 -31 -0.02 "HV leakage in microAmps" 11:04:00 AM 9.70E-005 -56 -11 -15 -7 -15 -6 -28 -28 19 13.5 15 3.89 3.79 -50 -50 -31.4 -0.07 11:11:00 AM 9.60E-005 -60 -11 -15 -7 -14 -6 -28 -28 17 13.5 15 3.89 3.8 -50 -50 -31.5 -0.03 11:23:00 AM 9.40E-005 -64 -11 -15 -7 -15 -7 -28 -29 15 13 15 3.89 3.8 -50 -50 -31.6 -0.03 11:36:00 AM 9.40E-004 -68 -11 -15 -7 -15 -7 -29 -29 7 13.5 17 3.9 3.8 -50 -50 -31.7 -0.03 "Start cool down" 11:39:00 AM 9.30E-004 -68 -19 "lo" -19 "lo" -18 -29 -29 0 13.5 15 0 0 -50 -50 -33.8 -0.02 11:45:00 AM 9.18E-005 -76 "#VALUE!" "lo" "lo" "lo" "lo" -29 -29 -4 13 14 0.73 0.73 -50 -50 -33.5 -0.06 "Start reheat" 11:56:00 AM 9.23E-005 -66 -16 -20 -11 -20 -11 -32 -32 9 12 18 3.89 3.79 -50 -50 -32.12 -0.07 "Took temp to 30deg in heating" 12:10:00 PM 9.06E-005 -70 -9 -10 -8 -10 -8 -30 -31 8 9 0 0.43 1.75 -50 -50 -30 -0.1 "Finished" 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 0 0 0 0 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 -10 -10 -10.7 -0.2 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 -20 -20 -16.2 0.27 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 -30 -30 -20.7 0.29 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 -40 -40 -24.4 0.31 10:42:00 AM 1.10E-004 -16 -3 -4 -3 -3 -1 -13 10 24 14 15 0 0 -50 -50 -27 -0.33 "28/9/06" 04:45:00 PM "Remount module" "29/9/06" 09:30:00 AM 1.50E-004 "NA" 21.75 21 22 22 22 25 25 24 11 10 0 0 0 0 0 0 "Start cool down" 09:39:00 AM 1.30E-004 "NA" -4.5 -5 -4 -5 -4 -14 -5 -4 18 0 0 0 0 0 0 0 "Irregular flow in CO2 system" 09:50:00 AM 9.74E-005 "NA" -10.25 -14 -7 -14 -6 -28 -30 29 14 18 3.88 3.78 -150 -200 -55 -0.38 "Powered and cold: taking data" 09:54:00 AM 1.00E-004 "NA" -6.75 -11 -3 -10 -3 -28 -32 18 13 18 3.87 3.78 -150 -200 -54 -0.43 "R side data" 10:02:00 AM 1.20E-004 "NA" -6.25 -10 -3 -10 -2 -27 -32 26 14 20 3.88 3.79 -200 -250 -64 -0.7 10:09:00 AM 1.20E-004 "NA" -8 -12 -4 -12 -4 -29 -32 21 13 30 3.93 3.79 -250 -300 -74 -1.1 10:18:00 AM 1.00E-004 "NA" -8 -12 -5 -12 -3 -36 -30 16 10 9 3.88 3.79 -250 -300 -73 -1.2 10:31:00 AM 1.00E-004 "NA" -8.5 -12 -6 -12 -4 -34 -34 18 11 13 3.92 3.79 -250 -300 -73 -1.3 10:43:00 AM 1.00E-004 "NA" -8.25 -12 -5 -12 -4 -34 -34 19 11 11 3.92 3.79 -250 -300 -73 -1.3 10:51:00 AM 1.00E-004 "NA" -8 -12 -5 -12 -3 -35 -32 19 11 11 3.92 3.79 -250 -300 -73 -1.5 10:58:00 AM 1.00E-004 "NA" -6.75 -11 -4 -10 -2 -35 -33 19 11 11 3.91 3.8 -250 -300 -72 -1.8 11:21:00 AM 1.00E-004 "NA" -4.5 -9 -2 -8 1 -35 -22 20 12 16 3.9 3.8 -250 -300 -73 -15.3 11:32:00 AM 1.10E-004 "NA" -8.25 -12 -5 -12 -4 -32 -34 15 12 16 3.91 3.8 -250 -300 -73 -24.3 "Current did hit -31 at peak" 11:46:00 AM 1.10E-004 "NA" -8.25 -12 -5 -12 -4 -32 -34 -5 12 18 3.91 3.8 -250 -300 -73 -3.5 "16/10/2006" 10:36:00 AM 1.00E+003 "NA" 22 22 22 22 22 22 22 0 0 0 0 0 0 0 0 0 0 -0.06 0 -10 -10 -10.3 -0.2 "Phi as expected " -20 -20 -15.6 -0.26 -30 -30 -20.2 -0.3 -40 -40 -23.9 -0.31 -50 -50 -26.9 -0.32 -60 -60 -29.7 -0.35 -70 -70 -32.6 -0.36 -80 -80 -35 -0.39 -90 -90 -37.4 -0.41 -100 -100 -39.7 -0.43 -110 -110 -41.9 -0.48 -120 -120 -44.1 -0.54 -130 -130 -46.1 -0.62 -140 -140 -48.5 -0.72 -150 -150 -50.6 -0.83 -160 -160 -52.9 -0.95 -170 -170 -55 -1.12 -180 -180 -57.2 -1.2 -190 -190 -59.2 -1.36 -200 -200 -61.6 -1.52 -210 -210 -64.5 -1.73 -220 -220 -67.4 -1.93 -230 -230 -71.3 -2.2 -240 -240 -76 -2.93 -250 -250 -84 -3.3 "19/12/2006" 05:05:00 PM 1.00E+003 -40 22 22 22 22 0 0 0 0 "20/12/2006" 09:37:00 AM 2.30E-003 -48 22 22 22 22 25 24 23 9 0 0 0 0 0 0 0 "Cooling problems. Gas not flowing well " 0 0 -0.3 -0.1 -10 -10 -10.3 -0.2 -20 -20 -15.6 -0.3 -30 -30 -20.3 -0.3 -40 -40 -20.4 -0.3 -50 -50 -27.8 -0.4 -60 -60 -30 -0.4 -70 -70 -32.5 -0.4 -80 -80 -35.3 -0.4 -90 -90 -37.6 -0.4 -100 -100 -40 -0.4 -110 -110 -42.3 -0.4 -120 -120 -44.7 -0.4 -130 -130 -46.8 -0.5 -140 -140 -49.3 -0.5 -150 -150 -51.6 -0.5 -160 -160 -53.9 -0.6 -170 -170 -56 -0.7 -180 -180 -58.5 -0.7 -190 -190 -60.7 -0.7 -200 -200 -63.3 -0.7 -210 -210 -65.7 -0.8 -220 -220 -68.9 -0.8 -230 -230 -72 -0.6 -240 -240 -75.3 -0.8 -250 -250 -80.5 -0.4 09:39:00 AM 2.30E-004 -54 "#VALUE!" "lo" "lo" "lo" "lo" -27 -17 23 13 18 3.84 3.76 -250 -250 -82.8 -0.3 09:45:00 AM 1.50E-004 -64 -13.25 -18 -9 -17 -9 -28 -30 18 14 22 3.87 3.79 -250 -250 -78 -0.5 09:48:00 AM 1.20E-004 -64 -12.75 -17 -9 -17 -8 -28 -31 14 14 20 3.88 3.79 -250 -250 -77.5 -0.5 "Currents went briefly positive" 09:53:00 AM 1.50E-003 -60 28.5 26 30 27 31 -22 -25 10 9 0 3.88 3.79 -250 -250 -66.9 -3.8 10:02:00 AM 1.40E-003 -62 24.5 22 26 23 27 -22 -24 10 8 0 3.88 3.79 -250 -250 -66.5 -3.5 "2nd thermal cycle" 10:14:00 AM 3.20E-004 -64 -15 -19 -11 -19 -11 -31 -32 -5 12 20 3.88 3.79 -250 -250 -75 -0.5 "Thermographs"